SATELLITE MODULES FOR ENERGY METERING

KIT FOR ROOM CLIMATE CONTROL AND METERING OF THERMAL AND WATER ENERGY

All our systems and products can be managed remotely via IoS and Android smartphones and via voice commands with Amazon Alexa and Google Home

Termogea APP - Apple store
Termogea APP - Google Play
Voice control of thermal systems via Amazon Alexa
Voice control of thermal systems via Google Home Assistant

PICO SAT MODULE

ROOM CLIMATE CONTROL AND METERING OF THERMAL, REFRIGERATING AND WATER ENERGY (DHW).

  • Zone valve with shutter.
  • Thermal energy meter DN 15 and sanitary meters DN 15.

Recommended flow rate thermal line 1.0 mc/h, sanitary lines 2.5 mc/h.

Pico Sat Module

Pico Sat Module

Pico Sat Module
Energy Meter

Energy Meter

Pico Sat Module Energy Meter
BOX

BOX

Pico Sat Module box

NANO SAT MODULE

ROOM CLIMATE CONTROL AND METERING OF THERMAL, REFRIGERATING AND WATER ENERGY (DHW).

  • Ball zone valve.
  • Thermal energy meter DN 15 and sanitary meters DN 15.

Recommended flow rate thermal line 1.2 mc/h, sanitary lines 2.5 mc/h.

Nano Sat Module

Nano Sat Module

Nano Sat Module
Energy Meter

Energy Meter

Nano Sat Module Energy meter
BOX

BOX

Nano Sat Module Box

MICRO SAT MODULE

ROOM CLIMATE CONTROL AND METERING OF THERMAL, REFRIGERATING AND WATER ENERGY (DHW).

  • Ball zone valve.
  • Heat meter DN 20 and sanitary meters DN 15.

Recommended flow rate thermal line 1.7 mc/h, sanitary lines 2.5 mc/h.

Micro Sat Module

Micro Sat Module

Micro Satellite Module
Energy meter

Energy meter

Energy mater for Micro satellite module
Box

Box

Box for Micro satellite module.

HIGH SAT MODULE

ROOM CLIMATE CONTROL AND METERING OF THERMAL, REFRIGERATING AND WATER ENERGY (DHW).

  • Ball Zone Valve.
  • Thermal energy meter DN 25 and sanitary meters DN 20.

Recommended flow rate thermal line 2.7 mc/h, sanitary lines 4.0 mc/h.

High Sat Module

High Sat Module

High Satellite module
Energy Meter

Energy Meter

High Satellite module Energy Meter
Box

Box

High Satellite Module Box

DOUBLE SAT MODULE

ROOM CLIMATE CONTROL AND FLUID HEAT TRANSFER WITH DIRECT AND MIXED DOUBLE SECTION.

METERING OF THERMAL, REFRIGERATING AND DOMESTIC HOT/COLD WATER ENERGY.

  • Temperature reduction system for radiant floors in thermostatic fixed point or climatic regulation version.
  • General zone ball valve.
  • Direct circuit zone ball valve.
  • Thermal energy meter DN 20 and sanitary meters DN 15.
  • Mixed line with inverter pump.

Recommended flow rate for sanitary lines 2.5 mc/h.

Double Sat Module

Double Sat Module

Double Satellite Module
Energy Meter

Energy Meter

Double satellite Module Energy Meter
Box

Box

Double Satellite Module Box

COMPENSATOR SAT MODULE

ROOM CLIMATE CONTROL WITH HYDRAULIC SEPARATOR.

METERING OF THERMAL, REFRIGERATING AND DOMESTIC HOT/COLD WATER ENERGY

  • Hydraulic separator.
  • Inverter circulator.
  • Heat meter DN 20 and sanitary meters DN 15.

Recommended flow rate of the thermal line 1.7 mc/h, sanitary lines 2.5 mc/h.

Compensator Module

Compensator Module

Compensator Satellite Module
Energy Meter

Energy Meter

Compensator Satellite Module Energy Meter
Box

Box

Compensator Satellite Module Box

CLIMA SAT MODULE

ROOM AND FLUID HEATER CLIMATE CONTROL WITH SINGLE MIXED SECTION.

METERING OF THERMAL, REFRIGERATING AND DOMESTIC HOT/COLD WATER ENERGY

  • Hydraulic compensator or ball zone valve.
  • Temperature reduction system for radiant floors in thermostatic fixed point or climatic regulation version.
  • Thermal energy meter DN 20 and sanitary meters DN 15.
  • Mixed line with inverter pump.

Recommended flow rate for sanitary lines 2.5 mc/h.

Clima Module with electronic regulator

Clima Module with electronic regulator

Clima Satellite Module with electronic regulator
Energy meter with electronic regulator

Energy meter with electronic regulator

Clima Satellite Module Energy Meter with electronici regulator
Clima Module with Thermostatic fixed point

Clima Module with Thermostatic fixed point

Clima Satellite Module with thermostatic fixed point
Energy meter with thermostatic fixed point

Energy meter with thermostatic fixed point

Clima satellite Module energy meter with thermostatic fixed point
Box

Box

Clima satellite Module box

PRESS SAT MODULE

ROOM CLIMATE CONTROL AND CONTROL OF THE DIFFERENTIAL PRESSURE OF THE USER THERMAL CIRCUIT.

METERING OF HEATING, REFRIGERATING AND DOMESTIC HOT/COLD WATER ENERGY – CHECK OF THE DHW CIRCLE.

The innovative AB-PM HP zone valve keeps the differential pressure of the thermal circuit constant in all system users, despite the presence of variations on the riser side.
In the satellite there is also a DHW recirculation line, where a volumetric counter and a thermostatic valve MTCV-A are installed.
Through this valve it is possible to guarantee domestic hot water to the user always ready, limiting the waste of energy due to continuous recirculation.

Press Sat Module

Press Sat Module

Press Satellite Module
Energy Meter

Energy Meter

Press Sat Module Energy Meter
Box

Box

Press Satellite Module Box

SANIT SAT MODULE

ROOM CLIMATE CONTROL AND INSTANT DHW PRODUCTION.

DHW AND THERMAL ENERGY METERING.

  • System for the instantaneous production of domestic hot water by means of a plate exchanger.
  • Ball zone valve.
  • Heat meter DN 20 and sanitary meters DN 15.
  • Inverter pump serving the thermal line and primary exchanger.

Recommended flow rate for sanitary lines 2.5 mc/h.

Sanit Module

Sanit Module

Sanit Satellite Module
Energy Meter

Energy Meter

Sanit Satellite Module Energi Meter
Box

Box

Sanit Satellite Module Box

COLLECTORS SATELLITE MODULE

THEMPERATURE ROOM CLIMATE CONTROL

METERING OF THERMAL, REFRIGERATING AND DOMESTIC HOT/COLD WATER ENERGY

  • Pair of brass collectors.
  • Ball zone valve.
  • Heat meter DN 20 and sanitary meters DN 15.

Recommended flow rate of the thermal line 1.7 mc/h, sanitary lines 2.5 mc/h.

Collectors module

Collectors module

Collectors Sateliite Module
Energy Meter

Energy Meter

Collectors Satellite Module Energy Meter
Box

Box

Collectors Satellite Module Box

SAT PICO CABINET

MULTI-USER CABINET FOR ROOM CLIMATE CONTROL SYSTEM AND METERING OF THERMAL ENERGY AND DOMESTIC HOT/COLD WATER.

Cabinet available from 2 to 5 units and containing insulated columns with the possibility of inserting a pipe for DHW recirculation.

Expected Energy meter SAT-Pico model, equipped with shutter zone valve, DN 15 thermal energy meter and DN 15 sanitary meters.

Recommended flow rate thermal line 1.0 mc/h, sanitary lines 2.5 mc/h.

Energy Meter

Energy Meter

Sat Energy Meter pico model for Pico Cabinet
Pico Cabinet

Pico Cabinet

Sat Pico Cabinet

SAT NANO CABINET

MULTI-USER CABINET FOR ROOM CLIMATE CONTROL SYSTEM AND METERING OF THERMAL ENERGY AND DOMESTIC HOT/COLD WATER.

Cabinet available from 2 to 5 units and containing insulated columns with the possibility of inserting a pipe for DHW recirculation.

Expected Energy meter SAT-Nano model, equipped with ball zone valve, DN 15 thermal energy meter and DN 15 sanitary meters.

Recommended flow rate thermal line 1.2 mc/h, sanitary lines 2.5 mc/h.

Energy meter

Energy meter

Sat Nano Energy Meter model for Nano Cabinet
Cabinet

Cabinet

Sat Nano Cabinet