I/O EXPANSION MODULES FOR HOME CLIMATE CONTROL SYSTEMS

Remote control from IoS and Android Smartphones
Vocal Control via Amazon Alexa and Google Home

Termogea APP - Apple store
Termogea APP - Google Play
Controllo vocale impianti termici - Amazon Alexa
Controllo vocale impianti termici - Google Home Assistant

I/O COMPACT MODULE (code CIO)

EXPANSION CARD

Features

  • Card with: 8 relay outputs – 2 outputs 0-10V – 3 inputs for T probes – 2 digital input.
  • Modbus expansion module for managing up to 8 terminals.
  • Actuator with 0-10V relay outputs that interfaces with the TSH or TST regulator, through Modbus.
  • Utilities up to a maximum load of 16 A can be connected to the relay outputs.
  • Installation on DIN bar.

ROOM PROBE BOARD WITH RELAY (code SND-THR)

T/H SENSOR WITH MODBUS RELAY – TEMPERATURE/HUMIDITY RECESSED BOX 503

Features

  • Relay board with active microprocessor sensor for measuring the ambient temperature and relative humidity. ModBus RTU protocol (RS485).
  • Prepared for control via IoS or Android smartphone. Mounting in box 503.
  • Available both with and without hole cover upon communication of the domestic series requested at the time of order.

RELAY MODULE 24 (code RCM-24)

RELAY MODBUS 24 OUTPUTS

Features

  • Relay board is the Modbus expansion module for the control and management of users up to a maximum load of 4A.
  • Installation on DIN bar.
Outputs wireless relay

WIRELESS RELAY (code Z-REL-1)

1 OR 2 OUTPUTS WIRELESS RELAY

Features mod. Z-REL-1

  • Nominal load current of AC output (resistive load): 1 X 10A/240 VAC.
  • Nominal load current of DC output (resistive load): 1 X 10A / 30 VDC.
  • AC output power (resistive load): 2300W (240 VAC).
  • DC output power (resisteive load): 240 W (24 VDC).

Features mod. Z-REL-2

  • Nominal load current of AC output (resistive load): 2 X 4 A/240 VAC.
  • Nominal load current of DC output (resistive load): 2 X 4 A/30 VDC.
  • AC output power (resistive load): 2 X 920 W (240 VAC).
  • DC output power (resisteive load): 2 X 96 W (24 VDC).

IN/OUT WIRELESS RELAY (code Z-REL-IN-OUT)

WIRELESS RELAY WITH 1 INPUT AND 1 OUTPUT

  • Nominal load current of AC output (resistive load): 1 X 10A/240 VAC.
  • Nominal load current of DC output (resistive load): 1 X 10A / 30 VDC.
  • AC output power (resistive load): 2300 W (240 VAC).
  • DC output power (resisteive load): 240 W (24 VDC).
Input outputs wireless relay
Wireless temperature dimmer

WIRELESS DIMMER 0-10V (code Z-DIM)

DIMMER 0-10V

Features

  • Power supply: 12-24 VDC (SELV).
  • Maximum control voltage (Sink): -20/+20 VDC.
  • Maximum control voltage (Source): 0-11 VDC.
  • Maximum electric current (Sink): 2 mA.
  • Maximum electric current (Source): 7 mA.

WIRELESS THERMOSTATIC VALVE (code Z-VALV)

Features

  • Open zwave.
  • Battery life (claimed): up to two years with default settings – stand-by/restart every 30 minutes.
  • Temperature: detection every minute.
  • Setpoint: from 4°C to 28°C (with step of 0’5°C).
  • Installation: compatible with Danfoss valve bodies and others via supplied adapters.
  • Alarms: low battery – no signal – child lock.
  • Transmission range: 30 m.

ANALOGUE INPUTS MODULE (code ANI-4)

MODULE WITH 4 ANALOGUE INPUTS

Features

  • Module with 4 analog inputs 0-10VDC/4-20mA. The module can be connected via RS485 with Modbus RTU protocol.
  • The module has 4 analog voltage inputs with range 0-10VDC or 4-20mA current selectable by jumper.
  • The value of the inputs is given as an integer multiplied by x100 (eg 103 -> 1.03mA).

ANALOG OUTPUT MODULE (code ANU-4)

MODULE WITH 4 ANALOG OUTPUTS

Features

  • Module with 4 analog outputs 0-10VDC/4-20mA. The module can be connected via RS485 with Modbus RTU protocol.
  • module has 4 analog voltage inputs with range 0-10VDC.
  • The value of the outputs can be set via RS485 using the Modbus RTU protocol.
  • The module stores the last value set in a non-volatile memory so that when it is switched on again the output will automatically assume the last set value.